400 research outputs found

    The Karlsruhe Astrophysical Database of Nucleosynthesis in Stars Project - Status and Prospects

    Get PDF
    The KADoNiS (Karlsruhe Astrophysical Database of Nucleosynthesis in Stars) project is an astrophysical online database for cross sections relevant for nucleosynthesis in the s process and the γ process. The s-process database (http://www.kadonis.org) was started in 2005 and is presently facing its 4th update (KADoNiS v1.0). The γ-process database (KADoNiS-p, http://www.kadonis.org/pprocess) was recently revised and re-launched in March 2013. Both databases are compilations for experimental cross sections with relevance to heavy ion nucleosynthesis. For the s process recommended Maxwellian averaged cross sections for kT=5-100 keV are given for more than 360 isotopes between 1H and 210Bi. For the γ-process database all available experimental data from (p, γ), (p, n), (p, α), (α, γ), (α, n), and (α, p) reactions between 70Ge and 209Bi in or close to the respective Gamow window were collected and can be compared to theoretical predictions. The aim of both databases is a quick and user-friendly access to the available data in the astrophysically relevant energy regions. © 2014 Elsevier Inc.Peer reviewe

    Models wagging the dog: are circuits constructed with disparate parameters?

    Get PDF
    In a recent article, Prinz, Bucher, and Marder (2004) addressed the fundamental question of whether neural systems are built with a fixed blueprint of tightly controlled parameters or in a way in which properties can vary largely from one individual to another, using a database modeling approach. Here, we examine the main conclusion that neural circuits indeed are built with largely varying parameters in the light of our own experimental and modeling observations. We critically discuss the experimental and theoretical evidence, including the general adequacy of database approaches for questions of this kind, and come to the conclusion that the last word for this fundamental question has not yet been spoken

    Cosmic-ray induced background intercomparison with actively shielded HPGe detectors at underground locations

    Full text link
    The main background above 3\,MeV for in-beam nuclear astrophysics studies with Îł\gamma-ray detectors is caused by cosmic-ray induced secondaries. The two commonly used suppression methods, active and passive shielding, against this kind of background were formerly considered only as alternatives in nuclear astrophysics experiments. In this work the study of the effects of active shielding against cosmic-ray induced events at a medium deep location is performed. Background spectra were recorded with two actively shielded HPGe detectors. The experiment was located at 148\,m below the surface of the Earth in the Reiche Zeche mine in Freiberg, Germany. The results are compared to data with the same detectors at the Earth's surface, and at depths of 45\,m and 1400\,m, respectively.Comment: Minor errors corrected; final versio

    Determination of gamma-ray widths in 15^{15}N using nuclear resonance fluorescence

    Full text link
    The stable nucleus 15^{15}N is the mirror of 15^{15}O, the bottleneck in the hydrogen burning CNO cycle. Most of the 15^{15}N level widths below the proton emission threshold are known from just one nuclear resonance fluorescence (NRF) measurement, with limited precision in some cases. A recent experiment with the AGATA demonstrator array determined level lifetimes using the Doppler Shift Attenuation Method (DSAM) in 15^{15}O. As a reference and for testing the method, level lifetimes in 15^{15}N have also been determined in the same experiment. The latest compilation of 15^{15}N level properties dates back to 1991. The limited precision in some cases in the compilation calls for a new measurement in order to enable a comparison to the AGATA demonstrator data. The widths of several 15^{15}N levels have been studied with the NRF method. The solid nitrogen compounds enriched in 15^{15}N have been irradiated with bremsstrahlung. The Îł\gamma-rays following the deexcitation of the excited nuclear levels were detected with four HPGe detectors. Integrated photon-scattering cross sections of ten levels below the proton emission threshold have been measured. Partial gamma-ray widths of ground-state transitions were deduced and compared to the literature. The photon scattering cross sections of two levels above the proton emission threshold, but still below other particle emission energies have also been measured, and proton resonance strengths and proton widths were deduced. Gamma and proton widths consistent with the literature values were obtained, but with greatly improved precision.Comment: Final published version, minor grammar changes, 10 pages, 4 figures, 8 tables; An addendum is published where the last section is revised: T. Sz\"ucs and P. Mohr, Phys. Rev. C 92, 044328 (2015) [arXiv:1510.04956

    Chaotic Phase Synchronization in Bursting-neuron Models Driven by a Weak Periodic Force

    Full text link
    We investigate the entrainment of a neuron model exhibiting a chaotic spiking-bursting behavior in response to a weak periodic force. This model exhibits two types of oscillations with different characteristic time scales, namely, long and short time scales. Several types of phase synchronization are observed, such as 1 : 1 phase locking between a single spike and one period of the force and 1 : l phase locking between the period of slow oscillation underlying bursts and l periods of the force. Moreover, spiking-bursting oscillations with chaotic firing patterns can be synchronized with the periodic force. Such a type of phase synchronization is detected from the position of a set of points on a unit circle, which is determined by the phase of the periodic force at each spiking time. We show that this detection method is effective for a system with multiple time scales. Owing to the existence of both the short and the long time scales, two characteristic phenomena are found around the transition point to chaotic phase synchronization. One phenomenon shows that the average time interval between successive phase slips exhibits a power-law scaling against the driving force strength and that the scaling exponent has an unsmooth dependence on the changes in the driving force strength. The other phenomenon shows that Kuramoto's order parameter before the transition exhibits stepwise behavior as a function of the driving force strength, contrary to the smooth transition in a model with a single time scale

    Dynamic clamp with StdpC software

    Get PDF
    Dynamic clamp is a powerful method that allows the introduction of artificial electrical components into target cells to simulate ionic conductances and synaptic inputs. This method is based on a fast cycle of measuring the membrane potential of a cell, calculating the current of a desired simulated component using an appropriate model and injecting this current into the cell. Here we present a dynamic clamp protocol using free, fully integrated, open-source software (StdpC, for spike timing-dependent plasticity clamp). Use of this protocol does not require specialist hardware, costly commercial software, experience in real-time operating systems or a strong programming background. The software enables the configuration and operation of a wide range of complex and fully automated dynamic clamp experiments through an intuitive and powerful interface with a minimal initial lead time of a few hours. After initial configuration, experimental results can be generated within minutes of establishing cell recording

    Cross section measurement of the astrophysically important 17O(p,gamma)18F reaction in a wide energy range

    Get PDF
    The 17O(p,g)18F reaction plays an important role in hydrogen burning processes in different stages of stellar evolution. The rate of this reaction must therefore be known with high accuracy in order to provide the necessary input for astrophysical models. The cross section of 17O(p,g)18F is characterized by a complicated resonance structure at low energies. Experimental data, however, is scarce in a wide energy range which increases the uncertainty of the low energy extrapolations. The purpose of the present work is therefore to provide consistent and precise cross section values in a wide energy range. The cross section is measured using the activation method which provides directly the total cross section. With this technique some typical systematic uncertainties encountered in in-beam gamma-spectroscopy experiments can be avoided. The cross section was measured between 500 keV and 1.8 MeV proton energies with a total uncertainty of typically 10%. The results are compared with earlier measurements and it is found that the gross features of the 17O(p,g)18F excitation function is relatively well reproduced by the present data. Deviation of roughly a factor of 1.5 is found in the case of the total cross section when compared with the only one high energy dataset. At the lowest measured energy our result is in agreement with two recent datasets within one standard deviation and deviates by roughly two standard deviations from a third one. An R-matrix analysis of the present and previous data strengthen the reliability of the extrapolated zero energy astrophysical S-factor. Using an independent experimental technique, the literature cross section data of 17O(p,g)18F is confirmed in the energy region of the resonances while lower direct capture cross section is recommended at higher energies. The present dataset provides a constraint for the theoretical cross sections.Comment: Accepted for publication in Phys. Rev. C. Abstract shortened in order to comply with arxiv rule

    Neuronal synchrony: peculiarity and generality

    Get PDF
    Synchronization in neuronal systems is a new and intriguing application of dynamical systems theory. Why are neuronal systems different as a subject for synchronization? (1) Neurons in themselves are multidimensional nonlinear systems that are able to exhibit a wide variety of different activity patterns. Their “dynamical repertoire” includes regular or chaotic spiking, regular or chaotic bursting, multistability, and complex transient regimes. (2) Usually, neuronal oscillations are the result of the cooperative activity of many synaptically connected neurons (a neuronal circuit). Thus, it is necessary to consider synchronization between different neuronal circuits as well. (3) The synapses that implement the coupling between neurons are also dynamical elements and their intrinsic dynamics influences the process of synchronization or entrainment significantly. In this review we will focus on four new problems: (i) the synchronization in minimal neuronal networks with plastic synapses (synchronization with activity dependent coupling), (ii) synchronization of bursts that are generated by a group of nonsymmetrically coupled inhibitory neurons (heteroclinic synchronization), (iii) the coordination of activities of two coupled neuronal networks (partial synchronization of small composite structures), and (iv) coarse grained synchronization in larger systems (synchronization on a mesoscopic scale

    Ultrasound-guided paravertebral puncture and placement of catheters in human cadavers: an imaging study

    Get PDF
    Background During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. Methods We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. Results The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. Conclusions We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural space
    • …
    corecore